Summary
PURPOSE: To assess the visual outcomes at distance, intermediate, and near following the implantation of a full visual range IOL in cataract surgery patients.
METHODS: This retrospective study included patients who had undergone bilateral implantation of a full visual range IOL (enVista Envy IOL, Bausch and Lomb). Outcome measures included assessment of monocular uncorrected visual acuities at distance, intermediate, and near at postoperative 3 weeks.
RESULTS: Postoperatively, the data of 16 eyes (8 patients) were available for analysis. The mean logMAR UDVA was 0.12±0.14 with 81.3% of eyes achieving UDVA of 20/30 or better postoperatively. The mean postoperative manifest refraction spherical equivalent (MRSE) was -0.30 ± 0.35 D, with 87.5% of eyes achieving MRSE within 0.50 D. The mean UNVA was 0.12±0.09 logMAR, with 71.4% of eyes achieving UNVA of 20/25 or better, postoperatively. The mean UIVA was 0.06±0.08 logMAR, with 85.7% of eyes achieving UIVA 20/25 or better.
CONCLUSION: enVista Envy full visual range IOL implanted in cataract patients showed good visual outcomes at distance, intermediate and near.